When you looking for dust sensor sds011, you must consider not only the quality but also price and customer reviews. But among hundreds of product with different price range, choosing suitable dust sensor sds011 is not an easy task. In this post, we show you how to find the right dust sensor sds011 along with our top-rated reviews. Please check out our suggestions to find the best dust sensor sds011 for you.
Reviews
1. Dust Sensor Detector Module Kit, PM2.5 PM10 High Precision Air Particle Detector, Digital USB Laser Dust Detection Sensor Air Purifier Air Conditioner Monitor Module SDS011
Feature
Accurate and Reliable Dust Sensor Detector: This Dust Sensor features is always used for detect the dust concentration, and it features with a good stability and consistency, you can get a relatively precise and consistance data about the air dust particle concentration through itQuick Response Sensor: This Air Particle Concentration Sensor is features with a quick response, and the data updates frequently, and the data update frequency is 1 HZ, so you can detect the air particle concentration accurately and immediately, so you can choose a relatively accurate method to deal with the air dust concentration
Easy to Operate: This Laser Dust Sensor Detector Module is designed with a small volume for easy and quick use and install, at the same time there comes with cable and USB, you can install it at ease, and it is a kind of digital and universal particle concentration sensor
Excellent Performance: This Air Particle Concentration Sensor works well. It is adopted with serial output, and built-in fan for easy integration, so you can get a stable data within a short time, and it also has a high resolution, and the resolution is 0.3ug/m3, so you can get the data immediately
Widely Use: This sensor is widely used to detect the air dust concentration during daily life. And it can be inserted into variable instruments related to the concentration of suspended particles in the air or other environmental improvement equipment to provide correct concentration data in time
Description
Specifications:Material: Plastic
Condition: 100% brand new and high quality
Weight: 60g
Technical Parameters:
NO. Item Parameter 1 Measuring output PM2.5, PM10 2 Range PM2.5: 0.0-999.9g/m3
PM10: 0.0-1999.9g/m3 3 Rated voltage 5V 4 Rated current 70mA10mA 5 Sleep current <4mA 6 Temperature range Storage environment: -20 ~ +60
Operation environment: -10 ~ +50 7 Humidity range Storage environment: Max.90%
Operation environment: Max.70% 8 Working atmosphere pressure 86KPa ~ 110KPa 9 Response time 1s 10 Serial data output frequency 1Hz 11 Min. particle diameter resolution Less than 0.3um 12 Counting efficiency 70%@0.3m
98%@0.5m
13 Relative error 15% and 10g/m3 maximum(25, 50%RH) 14 Power supply voltage 4.7~5.3V 15 Power supply power 1Wcurrent 200mA 16 Power supply voltage ripple 20mV 17 Product size Approx. 70 x 70 x 22mm / 2.75 x 2.75 x 0.86inch
Package List
1 x Laser Dust Sensor
1 x USB To TTL Module
1 x Cable
2. Seajunn Nova PM sensor SDS011 High precision laser pm2.5 air quality detection sensor module Super dust dust sensors, digital output
Description
Nova PM sensor SDS011 High precision laser pm2.5 air quality detection sensor module Super dust dust sensors, digital output3. iHaospace SDS011 Nova PM Sensor Laser PM2.5 Air Quality Detection Sensor Module Dust Sensor Air Conditioning Monitor Module
Feature
Accurate data: laser detection, stable and consistentFast response: scene change response time is less than 10 seconds
Easy to integrate: serial port output (or IO output can be customized), comes with a fan
High resolution: Resolution of particles with a minimum diameter of 0.3 m
Serial communication protocol: 9600 8 N 1
Description
Features:
Accurate data: laser detection, stable and consistent;
Fast response: scene change response time is less than 10 seconds;
Easy to integrate: serial port output (or IO output can be customized), comes with a fan;
High resolution: Resolution of particles with a minimum diameter of 0.3 m
Serial communication protocol: 9600 8 N 1
Output range:PM2.5: 0-999 ug/m3 , PM10 : 0-999 ug/m3
Period: 1004ms +1%
4. LIGHTHINKING Nova PM Sensor SDS011 High Precision Laser pm2.5 air Quality Detection Sensor Module Super dust dust sensors, Digital Output
Description
Nova PM sensor SDS011 High precision laser pm2.5 air quality detection sensor module Super dust dust sensors, digital output5. Bestol Nova PM sensor SDS011 High precision laser pm2.5 air quality detection sensor module Super dust dust sensors, digital output
Description
Nova PM sensor SDS011 High precision laser pm2.5 air quality detection sensor module Super dust dust sensors, digital output6. elinke PM sensor SDS011 High precision laser pm2.5 air quality detection sensor module Super dust dust sensors, digital output
Description
PM sensor SDS011 High precision laser pm2.5 air quality detection sensor module Super dust dust sensors, digital output7. Chironal Nova PM sensor SDS011 High precision laser pm2.5 air quality detection sensor module Super dust dust sensors, digital output
Description
Nova PM sensor SDS011 High precision laser pm2.5 air quality detection sensor module Super dust dust sensors, digital output8. Quickbuying 1PCS Original NOVA SDS011 Laser Dust Sensor PM2.5 PM10
Feature
1PCS ORIGINAL & Brand New NOVA SDS011 Laser Dust Sensor PM2.5 PM10Description
1PCS ORIGINAL & Brand New NOVA SDS011 Laser Dust Sensor PM2.5 PM109. 5PCS PM Sensor SDS011 High Precision Laser pm2.5 air Quality Detection Sensor Module Super dust dust Sensors, Digital Output
Feature
Output:Analog SensorType:Optical-Electronics Sensor
Material:Metal
Usage:Gas Sensor
Theory:Optical Sensor
Description
Output:Analog SensorType:Optical-Electronics Sensor
Material:Metal
Usage:Gas Sensor
Theory:Optical Sensor
is_customized:Yes
visin general
Check-sum: Check sum = DATA1 + DATA2 +... + DATA6.
PM2.5 valor: PM2.5 (g/m3) = ((PM2.5 Alta byte * 256) + PM2.5 byte bajo)/10
valor de PM10: PM10 (g/m3) = ((PM10 byte alto * 256) + PM10 byte bajo)/10
Unit Type: lot (5 pieces/lot)
Package Weight: 0.5kg (1.10lb.)
Package Size: 10cm x 10cm x 5cm (3.94in x 3.94in x 1.97in)
10. PM Sensor SDS011 High Precision Laser pm2.5 air Quality Detection Sensor Module Super dust dust Sensors, Digital Output
Feature
Output:Analog SensorType:Vacuum Sensor
Material:Metal
Usage:Level Sensor
Theory:Optical Sensor
Description
Output: Analog SensorType: Vacuum Sensor
Material: Metal
Usage: Level Sensor
Theory: Optical Sensor
is_customized: Yes
overview
The SDS011 using the laser dispersion principle, can obtain the concentration of particles between 0.3 to 10m in the air. with digital output and built-in fan is stable and reliable.
features
1. Accurate and Reliable: laser detection, stable, good consistency;
2. Quick response: response time is less than 10 seconds when scene changes;
3. Easy integration: output UART (or output IO can be customized), built-in fan;
4. High resolution: resolution of 0.3 g / m3.
scope
PM2.5 detector; Purifier.
Operating principle
The use of laser dispersion principle:
Light scattering can be induced when they pass through the particle detection area. the scattered light is transformed into electrical signals and these signals are amplified and processed. The number and diameter of the particles can be obtained by analysis because the waveform signal has certain relationships with the diameter particles.
Technical parameters
about the service life < br /> Lifespan is the key parameter of laser powder sensor. The laser diode of this sensor has high quality and its useful life is up to 8000 hours. If you need the data in real time (such as detector), you can use the default setting which measures at the frequency of 1 times per second. Because of the demand in real time is not very high (such as filter, air quality monitoring, etc.), you can use the discontinuous work method to prolong the service life. For example, you can start the sensor for 30 seconds per minute. If you have any other requirement, please contact us,