Feature

K-type thermocouple temperature input acquisition, effective control of the temperature of -30 to 500 degrees, can be replaced by the high-temperature K-type temperature probe up to 999 .

The controller uses industrial microcomputer control system, stable performance, simple operation.

Using K-type thermocouple temperature probe, with easy installation, high temperature, long life and other advantages.

Applications: electric control boxes, control cabinet, boilers, gas stoves, car engines and other places of high temperature.

If you for any reason are not happy with any product supplied , please do not hesitate to contact us and we will do our best to solve your problem .

Description

Display Color: Blue.
Input voltage: DC24V
Motherboard Power: <3W
Temperature range: -30 ~ 999
Measuring input: K-type thermocouple
Temperature measurement accuracy: 1
Input Type: one relay output
Output Current: 10A MAX.
Display window: 38 * 20mm
Size: 79 * 51 * 27mm (L * W * H)

Buttons, lights and fault codes:
Power emperor window displays the current temperature in real time;
Ent: Enter, according to a determined set value, press switch can be realized.
SET: setting key, press once to enter the main menu (F1-F5);
"+" Plus key: Increase panel display value;
"-" Minus key: decrease the value of the panel display;
LLL / HHH: Sensor fault or sensor not connected;
Mode / Cooling: lights shows that the current mode is a cooling mode;
Mode / heating: Lit describes the current mode is a heating mode;
Start: Lit explained that it had started the output relay is closed.
Internal Setting instructions:
Press the SET panel display F1-F5, can be set for each parameter by key operation
F1: set the desired temperature (-50 ~ 999 )
F2: Setting the operating mode H = Heating, C = cooling.
F3: hysteresis setting (that is, lower the number of degrees working again).
F4: temperature correction, real-time display value = value + correction value.
F5: high temperature alarm, reaches this temperature the thermostat will prompt alarm.

Instructions:
1, the equipment is turned off, hold down the "+" and "-" keys, the power is turned on, displays "888", release the button. (This step restores the factory settings).
2. Set the stop temperature: enter F1 mode. To stop the number of degrees is set to the number of degrees.
3. Set the mode: F2 to enter setup. Heating mode is set to H, the refrigerant is set to C.
4. Set Backlash: enter F3 setting, hysteresis temperature range = maximum - minimum.